Secure by Design – Secure by Default – Verified on the Wire
The era of treating an entertainment lighting networks as secure because it is isolated from the Internet is long behind us. The reasons are varied: hacking and ransoming of networks has become both easier and more sophisticated with the dawn of the AI age. Cybersecurity legislation, particularly the EU Cyber Resilience Act (CRA / Regulation (EU) 2024/2847) and the UK PSTI Act, places the burden for compliance squarely with the manufacturer.
The two concepts that underpin modern cyber security are Secure by Design and Secure by Default. While they sound similar, they have very specific and different meanings. Secure by Design means that the product designer and manufacturer must implement security from the very first stages of the design process. Secure by Default means that the product must reach the customer with all the secure features enabled and any unsecure features disabled.
However, it is not the manufacturer’s responsibility to stop the customer from defeating those settings. If the technician that installed your gateway disabled the password or re-enabled an unsecure protocol, vulnerabilities are reintroduced.
PENpal™ attacks the installation from the outside. It behaves as an adversary. It checks Secure by Design: do the products support secure protocols. Then it checks that the network is still Secure by Default: is the web browser protected? Are the unsecure protocols disabled?
There are two ways to use PENpal:
1) Interactive Workbench
Select specific devices and run targeted test vectors on demand. Drill into individual failures, monitor live packet responses and repeat tests while stepping through code in your development environment.
2) Automated Audit Run
Execute a full, non-destructive audit across the entire rig. PENpal catalogues all discovered devices, groups identical models to optimise test coverage, probes network-wide exposure, and compiles a comprehensive, tamper-evident Audit Report.
PENpal’s digitally signed Audit Report bridges the gap between raw packet captures and formal regulatory compliance:
- Full test analysis.
- EU CRA Annexe I: Provides comprehensive cross reference.
- Remedy Guidance: The report categorises findings into immediate actions that site operators can resolve plus engineering defects that require firmware fixes from the equipment manufacturer.
- Integrity & Authenticity: The report is digitally signed and all related data includes SHA-256 integrity hashes to provide defensible and auditable evidence.
- Threat Catalogue: The threat catalogue includes credential and secret probing, replay attack and sequence tampering, DoS (Denial of Service), epoch regression, CPU exhaustion, downgrade protection analysis, security event violation reporting tests and much more.
Interpreting Test Results
Every probe executed by PENpal produces one of four standardised outcomes:
- Pass: The attack or exploit probe was tried and failed to compromise the target.
- Advisory: The test could not be run or was deliberately skipped. This is typically because the target does not implement a particular protocol or feature set.
- Warning: The device reacted when it should have remained silent, or exhibited an ambiguous behaviour that warrants investigation. An exposed weakness was observed, but no unauthorised state change, privilege escalation, or access was confirmed.
- Fail: PENpal successfully gained unauthorised control, modified operational state, bypassed cryptographic authentication, or disrupted device availability.
Subscriptions & Licences
PENpal is licensed on an annual subscription basis. Choose the licence tier that matches your operational requirements:
Manufacturer Licence (PEN-SUB-MAN):
Designed for equipment manufacturers and R&D teams. Covers one workstation seat and locks testing to your organisation’s registered ESTA Manufacturer ID (ManID). Includes self-service node-locked licence transfers between workstations.
Manufacturer Add-On (PEN-SUB-ADD):
Extends an active Manufacturer Licence to cover an additional ESTA Manufacturer ID, allowing parent companies or multi-brand engineering teams to audit multiple product lines under one roof.
Venue Licence (PEN-SUB-VENUE):
Single-site subscription for permanent venues, theme parks, cruise ships, studios and fixed installations. Unlocks testing for all connected devices on the venue’s lighting network, regardless of manufacturer. Strictly restricted to internal facility use.
Consultant Licence (PEN-SUB-CONSULT):
For consultants, rental houses, and show-prep facilities. Unlocks testing for all network devices and includes full rights to generate client-facing audit reports. Excludes manufacturer product R&D and Technical File authoring.
Additional Workstation Seat (PEN-SUB-SEAT):
Adds an additional concurrent seat to an existing base licence. Valid for direct company employees and branch offices; pProhibited for use by third-party contract manufacturers.
Which Licence Do I Need?
Example 1: An equipment manufacturer auditing their own products.
Need: An engineering team with one primary test engineer developing DMX/RDM/Sig-Net gateways under a single ESTA ID.
Solution: Purchase 1 × PEN-SUB-MAN.
Example 2: A manufacturer with separate R&D and QA test benches.
Need: A single brand developing products across two physical laboratory benches or workstations.
Solution: Purchase 1 × PEN-SUB-MAN and 1 × PEN-SUB-SEAT (2 seats total for a single ESTA ID).
Example 3: A manufacturing group with two daughter brands.
Need: A company producing fixtures under two distinct ESTA Manufacturer IDs with engineering teams in two offices.
Solution: Purchase 1 × PEN-SUB-MAN, 1 × PEN-SUB-ADD, and 1 × PEN-SUB-SEAT (2 seats total covering 2 distinct Manufacturer IDs).
Example 4: A theatre, opera house or cruise ship.
Need: An in-house technical team needing to audit their house rig and document facility cybersecurity compliance.
Solution: Purchase 1 × PEN-SUB-VENUE (unlocks all connected hardware on-site, single seat).
Example 5: A rental staging house or systems integrator.
Need: A commercial hire facility checking prep rigs before tour dispatch and issuing signed cybersecurity health-check certificates to production clients.
Solution: Purchase 1 × PEN-SUB-CONSULT (unlocks all brands, includes client report distribution rights).
How to purchase a subscription
- Use the ‘Add to cart’ button above and checkout to order your preferred subscription (you will be required to enter the ESTA Manufacturer Code of your organisation, unless purchasing a Venue or Consultant licence).
- Install the NETworkshop package.
- Keep an eye out for an email from us containing your proforma invoice (usually within 1-2 working days). Once you have made the payment and the funds have cleared, you will receive another email containing a licence code to activate the subscription features of PENpal within NETworkshop.
- To activate your licence, navigate to the ‘Premium’ menu in NETworkshop. Select ‘Premium Feature Licence Manager’. Enter your activation code and press the Activate button.
Resources




